Curtains (drapery)

Italian UNI 9177, 9174 and 8456 (Classe Uno)

 
Official standard:

Principle

The spread of flame is measured along the sides of a vertical or horizontal surface of a specimen exposed to a flame and a radiant panel. The after-glow, damaged zone and dripping are also observed.

Test method

The radiant panel and pilot flame are ignited. The burner and the vertically oriented specimen are then positioned. The time to reach the different marker threads is recorded. The average velocity is calculated to reach the flame spread velocity. The damaged zone and dripping and flaming debris are observed. Based on the observations of flame spread, damaged zone and dripping and flaming debris, the material can be classified in levels:  

LevelFlame spread velocityDamaged zonePeriod of after glowdripping
1Not measured (flame failed to reached 3rd mark=< 300mm=< 180sNo drops or flaming debris
2=< 30mm/min> 300mm and < 600mm>180s and < 360sDrops or flaming debris extinguishing after 3s
3> 30mm/min>= 600mm>= 360sDrops or flaming debris not extinguishing after 3s
 

Result

The levels are multiplied with a factor.                                 

Flame spread velocity            à  x2                               

Damaged zone                        à  x2                               

After-glow time                      à  x1                               

Dripping                                  à  x1 for wall  x2 for ceiling 

The sum of the levels of behaviour multiplied by the correction factors give the products category (I to IV).    

Products categorySum
    wall ceiling
 I 6-8 7-9
 II 9-12 10-13
 III 13-15 14-17
 IV 16-18 18-21
   
 